...and apply a very low input signal when running the transient
      test.
    
    Le 30/12/2024 à 11:43, John Woodgate a
      écrit :
    
     
				
					
						
							переключити цитоване повідомлення
						
						Показати цитований текст
					
					
					
      
      1.Use.TRAN analysis, not .AC, because that
          doesn't show non-linearity.
      2. Check that the current through the output
          devices is very small with no input signal.
        
      On 2024-12-30 10:36, dlwarr911 via
        groups.io wrote:
      
      
        
        If I build a Class B amplifier (all have cross over
          distortion) What do I have to do, to see cross over in a
          trace...
        All I get is a perfect looking sign wave... What would be
          the analysis and steps to do this...??
         
        Any thoughts on this would certainly be appreciated.....
          Thanks....
      
      -- 
OOO - Own Opinions Only
Best Wishes
John Woodgate
Keep trying