Re: Measuring Attenuators


 

The minimum frequency of the SAA2 is listed as 50 kHz. The minimum of the
H4 is listed as 10 kHz. It doesn't look like it will work. You might
squeeze in the upper edge of your range with the H4, but not the lower
end.

Zack W9SZ

On Fri, Dec 13, 2024 at 6:18 AM Ken Morrow via groups.io <ken.morrow586=
gmail.com@groups.io> wrote:

I have a question about measuring filters below the low end of any Nanovna.

Is it possible to extrapolate both S21 and S11 down to DC on the Nanovna?
I am looking for a way to measure some low pass filters I built from 0 to
~20KHz (audio range) without costing a ton of money. I do not have access
to a Frequency Response Analyzer. Any thoughts or suggestions would be
very much appreciated.
Thank you,
Ken M.