#hardware

Diagnose unresponsive ch1 port on the nanovna
Is it possible to somehow verify that the U551 chip is the one causing problems?
Від tedvtorov@... · #38678 ·
Diagnose unresponsive ch1 port on the nanovna
It is possible that U551 has been damaged.
Від Hugen · #38669 ·
Diagnose unresponsive ch1 port on the nanovna
Here are the pictures of the front and back of the circuit board of the nanovna in as high of a resolution as I can provide with the metal shielding removed.
Від tedvtorov@... · #38657 ·
Diagnose unresponsive ch1 port on the nanovna
My bad, the 30ghz was a typo, the s-a-a-2 goes up to 3ghz. I am new to groups.io, so the pictures didn't attach properly. Hopefully they attach this time. I will add more closeup pictures of the circu
Від tedvtorov@... · #38655 ·
Diagnose unresponsive ch1 port on the nanovna
Yes you are right, I had just spent a while reading posts between Eric and a couple of users on the tinysa site and had forgotten that I had switched sites before replying. ___________________________
Від M0CNL · #38653 ·
Diagnose unresponsive ch1 port on the nanovna
Erik has nothing to do with VNA products - he manufactures the tinySA... Th OP has a product which is an owocomm design.
Від Roger Need · #38652 ·
Diagnose unresponsive ch1 port on the nanovna
Firstly any nano vna advertised as performing up to 30GHz is making false claims about its specifications. Secondly it sounds like you didn’t discharge any static from the antenna before connecting th
Від M0CNL · #38651 ·
Diagnose unresponsive ch1 port on the nanovna
Hello, I recently purchased a nanovna s-a-a-2 (hardware version v2_2, 50k-30ghz, owocomm design), and after around 2 weeks of work the measurements on the s11 port decided to malfunction. At the time
Від tedvtorov@... · #38650 ·
Model identification and proper firmware
None of these are 'clones', they are all copies with slight variations. As the original design was open-source, anyone can manufacture these. All the units above are nanoVNA-H and you can use any firm
Від Larry Rothman · #37749 ·
Model identification and proper firmware
Hello I have this nanovna labelled "-H", but from info online (including the wiki here) it seems to have the PCB case from the original nanovna along with maybe a -H pcb? The info screen says "NanoVNA
Від dev@... · #37743 ·
Calibration Standards Holder
Punch out the plastic and the pins to reduce the wear of the standards. <landrjoh@...> wrote:
Від Dragan Milivojevic · #37568 ·
Calibration Standards Holder
I got tired of trying to keep track of all those little SMA calibration standards and adapters that I keep with my NanoVNA, so I made a thing! It's a small pcb that uses common 1/4" wide edge mount SM
Від AA7US · #37565 ·
Electron Spin Resonance Studies using the Nano VNA
There is no way that I know of to do this, an amplifier is a one-way path. The gain and reverse isolation of the amplifier would not allow a useable reflected signal to flow back to the VNA to be meas
Від Donald S Brant Jr · #35059 ·
Electron Spin Resonance Studies using the Nano VNA
Can't that be calibrated out in advance using attenuators.
Від F4WCV · #35056 ·
Electron Spin Resonance Studies using the Nano VNA
Putting an amplifier after the VNA port 1 would result in measuring the S11 of the amplifier not the resonator. AFAIK to do this kind of measurement with an amplifier would require access to the inter
Від Donald S Brant Jr · #35050 ·
Electron Spin Resonance Studies using the Nano VNA
Proposed VNA electron-spin probe... Use the NanoVNA's S11 measurement mode to probe a high-Q resonator enclosing sample material. NanoVNA generates the RF, and also detects the RF signal. When electro
Від Glen Leinweber · #35043 ·
Electron Spin Resonance Studies using the Nano VNA
Yes the DC field is just the standard Helmholtz coil. Cavity design and impédance matching with a nanovna or Robinson oscillator set up? https://youtu.be/OnYT6L6XdIg?si=pcRqlWsurSd3Hrps
Від F4WCV · #35041 ·
Electron Spin Resonance Studies using the Nano VNA
Interesting app, similar to a grid-dip type app, where a LC resonator is probed. I'd imagine a high-Q external resonator would be needed. With 50-ohm source and 50-ohm load, high loaded resonator Q is
Від Glen Leinweber · #35024 ·
Electron Spin Resonance Studies using the Nano VNA
Has anybody tried using their nanovna to do ( ESR) election spin résonance experiments?
Від F4WCV · #35014 ·
Nanovna-H problem
Many schematics can be found on Hugen's github repo - some as *.png or *.jpg, but you should be able to convert them to *.pdf yourself: https://github.com/hugen79/NanoVNA-H/tree/master/doc HTH Martin
Від Ho-Ro · #34500 ·