any working NTP servers
The 3- and 4- series apply DST (Summer/Winter Time) based on the selected/configured timezone. The 2-series have no intrinsic concept of time zones but can configure DST (from among ‘none’, ‘US’, ‘sou
Від Lincoln King-Cliby · #255522 ·
any working NTP servers
The first two of those should be working; also time.windows.com has been an option in the past. NTP is on Port 123 and is not in any way like HTTP so if you're literally using http://worldtimeapi.org/
Від Lincoln King-Cliby · #255498 ·
Best 32" TV for control integration
There are hundreds of digital signage options out there (LG, Samsung, Sharp/NEC, Philips, ...) but not sure about UK availability.... But The HD-CTL-101 (https://www.crestron.com/Products/Control-Hard
Від Lincoln King-Cliby · #255438 ·
Any way to stop DM Tool from timing out
CPU2 or CPU3 card? If a CPU3 card you may be up against the idle timeout auto logout that all 3- and 4- series processors have by default. There is a command that you can used to adjust the time or di
Від Lincoln King-Cliby · #255424 ·
Global Cache IP2IR sensor input (RMC4)
Sorry, I initially replied on mobile and was a bit harried… For multicast you need to use the multicast group ID as the address so that the processor/OS knows it needs to send the IGMP Join message to
Від Lincoln King-Cliby · #255374 ·
Global Cache IP2IR sensor input (RMC4)
You would not be able to use 0.0.0.0 in this case on a properly configured network as the device needs to send a "join" message to the switch to let it know that it is interested in getting that data.
Від Lincoln King-Cliby · #255372 ·
4-Series Processors, SSL, and VPN connection
Have you confirmed the correct subnet mask and default route on the processors? If your single user VPN gets an address on the same subnet as the devices there is no routing (at least as far as the de
Від Lincoln King-Cliby · #255333 ·
C9300 Multicast flooding to NVXs
So two things... L2 Multicast will always go to the querier, best practice in simple configurations IME is to have the querier on the switch hosting the majority of encoders and you may need to make s
Від Lincoln King-Cliby · #255315 ·
Multiple One-Shot Bug
Any chance you have a jammed signal (making the output behave like a logic gate)? Get Outlook for Android
Від Lincoln King-Cliby · #255068 ·
TCP/IP ISC Server-Client
Are you doing intra-VC4 communication or VC4-to-edge communication? If intra VC4, the Interprogram Communication slot has been working really well (watch me get a call about this now...) for passing i
Від Lincoln King-Cliby · #255059 ·
TCP/IP ISC Server-Client
Is there a reason you need to use that flavor? By chance have you tried pulsing the update_request on the ethernet offline manager device extender? I’ve completely abandoned the 3-series ISC in all of
Від Lincoln King-Cliby · #255049 ·
Controlling Projector through DM-RMC-4K-Scaler Ethernet port
Unless someone has changed some very arcane default settings that are not exactly easy to find – I think they’re console only and even when I need them I have to Google them (and it’s been 3+ years si
Від Lincoln King-Cliby · #254871 ·
IV-CAM-I12-B / HD-EXT-USB-2000-C Compatibility
I have been told by a swirl technology director when I was looking at ways to cost control a design that the IV cams will downshift to USB2 (with the corresponding loss in maximum res/frame rate capab
Від Lincoln King-Cliby · #254751 ·
Crestron TSD-2220 as PC touch monitor?
Note also that the DGE is compatible with a large number of 3rd party USB touchscreens if you wanted to look at it from a different direction. For example with one of my clients I’ve deployed a decent
Від Lincoln King-Cliby · #254660 ·
Crestron TSD-2220 as PC touch monitor?
I can’t remember for the 2220 but the 2020 was literally an COTS Sharp 20” touchscreen with a Swirl on the back (and even that wasn’t always the case) so I would think it functioning as a generic HID
Від Lincoln King-Cliby · #254638 ·
DM-NAX-AMP-X300 assistance request
The documentation in SIMPL is… NOT stellar to the point where it may have been more useful if it wasn’t there If you have access to the unit the web GUI gives enough breadcrumbs to mostly figure it ou
Від Lincoln King-Cliby · #254600 ·
UniFi adds Crestron Pro AV support
The real tests in any multicast deployment is not the number of outputs but rather the number of inputs (and number of switches and the handling of multicast between them) – in theory a completely unm
Від Lincoln King-Cliby · #254594 ·
BSS Soundweb London Experiences
I agree with the premise that QSC Q-SYS or Biamp Tesira seems like a more logical choice in 2024 than Soundweb (keeping in mind also, IIRC, that the current ultimate parent only bought the conglomerat
Від Lincoln King-Cliby · #254555 ·
DMC-4K-CO-HD with a DM-RMC-100-C
The RMC-100-C (and non-scaling derivatives) do nothing meaningful to the video stream beyond the HDBT->HDMI conversion so the HDCP2 part doesn’t surprise me since that handshake is between the display
Від Lincoln King-Cliby · #254448 ·
HD-MD8X2 questions
Sounds like an overscan issue; sounds like the switcher is presenting different EDID to the source than the TV directly is which you can usually fix either by copying the EDID from the sink (e.g. TV)
Від Lincoln King-Cliby · #254216 ·