DSP parametric EQ control
#programming
#values
NICE! That worked. I used a gesture canvas as a way to move around a parametric EQ. The Y axis controls gain and the X axis controls frequency. I made a S+ module that builds a string that looks like:
Від
D_a_n_e
· #253776
·
|
DSP parametric EQ control
#programming
#values
I think you’re looking for analog logic symbol called “log with limits”. I haven’t poked at the maths for it, but frequencies are a logarithmic scale. You may have to poke at the numbers a bit to get
Від
Hood, Steven
· #253759
·
|
DSP parametric EQ control
#programming
#values
Hi All, I'm seeking a way to control a filter's frequency in a parametric EQ block in Biamp. I have successfully achieved control of it in a linear sense, but the problem is that the frequency range o
Від
D_a_n_e
· #253758
·
|
#cp3 #crestron #programming #simplwindows
#cp3
#crestron
#programming
#simplwindows
I think the Cresnet port -IS- available on a 3-series processor in Slave mode. Answer ID 5232 describes it, and I'm fairly certain I've done it before.
Від
Tony Golden
· #252567
·
|
#cp3 #crestron #programming #simplwindows
#cp3
#crestron
#programming
#simplwindows
EISC for sure. I'd put only my button presses and feedback to the CP3, and do any lighting logic local to the mc3. I'm not sure you can use an eslave device's gateway, I know you can't use it as a cre
Від
lokikallas
· #252565
·
|
#cp3 #crestron #programming #simplwindows
#cp3
#crestron
#programming
#simplwindows
Your idea is the best, cresnet is about 38400 baus rate, super slow. You can also try the EISC but it will requiere having two running program and get things synchronized
Від
Deuterios
· #252557
·
|
#cp3 #crestron #programming #simplwindows
#cp3
#crestron
#programming
#simplwindows
I would make the MC3 a slave. That way all of the IOs including the EX gateway will be available in the CP3. I am embarrassed to say that I am not sure about the cresnet. I would assume that would nee
Від
Matt Jones
· #252556
·
|
#cp3 #crestron #programming #simplwindows
#cp3
#crestron
#programming
#simplwindows
Hello, Here's my setup, I replaced a MC3 with a CP3N (RS-232 and the three IR functions have been moved over from the MC3) but I also have a Crestron CLW-DIMEX-P controlled by the built-in MC3's RFGW-
Від
dsmith
· #252555
·
Змінено
|
Problems with Simpl+ TCP Client to Simpl TCP Server through XSIG
#cp3
#EISC
#programming
#simpl
#splus
Hello again all! I figured it out, mostly by finding another thread on here: https://groups.io/g/crestron/topic/udp_socket_stumped/35800731?p= As Kool Aid-Drinker in that thread said: "Looks like the
Від
cnyitrai@...
· #252500
·
|
Problems with Simpl+ TCP Client to Simpl TCP Server through XSIG
#cp3
#EISC
#programming
#simpl
#splus
Hello! I'm running into a problem that I'm struggling to figure out, I'm communicating between two DMPS3 systems. I wrote my own TCP client in Simpl+ that accepts a target IP, which connects to a Simp
Від
cnyitrai@...
· #252486
·
|
C# Pro Door lock
#programming
#simplsharppro
Does anyone have an example of Home-Connect-DL door lock? I can't seem to find any info on it. Thanks
Від
JMeyer
· #252453
·
|
Planar VC9 module/commands
#crestron
#planar
#programming
Late to this party, but did you end up getting anything written for the VC-9. We have a VC4 that we are getting ready to do, and would rather not start from scratch. It seems RS232 over IP is the way
Від
brent.bensten@...
· #250246
·
|
Off State Power Button Behavior
#programming
Hey Caleb! Yeah, I think client education almost makes this a non-issue, but it's just something I've considered occasionally over the years. Thanks for sharing!
Від
Jonathan Troutman
· #249943
·
|
Off State Power Button Behavior
#programming
We’ve done: Power button = Off | source selects source turns room on. This is my preferred method as the operation is always the same. Power button always turns the room off, source always turns the r
Від
Caleb Radecky
· #249942
·
|
Off State Power Button Behavior
#programming
Yeah, that's how we've always done it too.
Від
Jonathan Troutman
· #249941
·
|
Off State Power Button Behavior
#programming
Power is off, source is On or source select depending on system state
Від
monticellog@...
· #249940
·
|
Off State Power Button Behavior
#programming
Just curious how other programmers handle the power button, or more specifically, the power button when the zone is in the off state. My company has always used the power button solely to turn a zone
Від
Jonathan Troutman
· #249939
·
|
Controlling DMPS3-200-C from QSC control nano.
#programming
As far as I know there is no separate API for the DMPS line, so you would need to write a program for the DMPS3-200-C that accepts custom commands over TCP from your QSC processor and then selects the
Від
Andy Ross
· #249247
·
|
Controlling DMPS3-200-C from QSC control nano.
#programming
Hello guys. I work as a Qsys freelance programmer. I have this one project where QSC control nano is being used as a control processor and dmps3-200-c simply as a switcher with 2 HDMI inputs and 1 DM
Від
smartguyjb818@...
· #249240
·
Змінено
|
Access RMC Scaler (via DM-MD) from SSH or Telnet
#programming
Yes, Lincoln is correct. You want to use the "uprogcmd" symbol. Not the "console" symbol as I incorrectly stated. That's what I get by doing thing from memory rather than looking at what I actually ha
Від
Steve Kuehn
· #247818
·
|